AR730

Home / Product / AR730

AR730

Home / Product / AR730

specification

Remarks

When configuring cards, ensure that the total power of the configured cards does not exceed 37 W or contact technical support engineers to obtain more suggestions.

Installation type

Rack,Work bench,Against the wall

Dimensions without packaging (H x W x D) [mm(in.)]

– Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 220.4 mm (1.75 in. x 17.41 in. x 8.68 in.) – Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 225.2 mm (1.75 in. x 17.41 in. x 8.87 in.)

Dimensions with packaging (H x W x D) [mm(in.)]

90 mm x 390 mm x 570 mm (3.54 in. x 15.35 in. x 22.44 in.)

Weight with packaging [kg(lb)]

4.6 (10.12)

Weight without packaging [kg(lb)]

3.2 (7.04)

Console port

RJ45

RTC

Supported

Maximum power consumption [W]

33

Power supply mode

AC built-in

Number of power modules

1

Rated input voltage [V]

100 V to 240 V, 50 Hz/60 Hz

Input voltage range [V]

90 V to 264 V, 47 Hz to 63 Hz

Maximum input current [A]

2

Maximum output power [W]

70

Safety regulation certification

IEC/EN/UL60950-1 IEC/EN/UL62368-1 GB 4943.1

EMC certification

EN 55032 EN 55035 CISPR 32 GB 9254 EN 55024 CISPR 24 GB/T 17618 EN 300 386 VCCI-CISPR 32 AS/NZS CISPR32 IEC 61000-3-2/EN 61000-3-2 IEC 61000-3-3/EN 61000-3-3

Type of fans

Built-in

Heat dissipation mode

Air cooling

Airflow direction

Left to right

Extended slots (standard configuration)

2 x SIC

Number of service board slots

2

Noise at normal temperature (acoustic power) [dB(A)]

52.3 dB(A)

Long-term operating temperature [°C(°F)]

0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage temperature [°C(°F)]

-40°C to +70°C (-40°F to +158°F)

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Long-term operating altitude [m(ft.)]

< 5000 m (16404.2 ft.)

Availability

0.9999924012

specification

Remarks

When configuring cards, ensure that the total power of the configured cards does not exceed 37 W or contact technical support engineers to obtain more suggestions.

Installation type

Rack,Work bench,Against the wall

Dimensions without packaging (H x W x D) [mm(in.)]

– Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 220.4 mm (1.75 in. x 17.41 in. x 8.68 in.) – Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 225.2 mm (1.75 in. x 17.41 in. x 8.87 in.)

Dimensions with packaging (H x W x D) [mm(in.)]

90 mm x 390 mm x 570 mm (3.54 in. x 15.35 in. x 22.44 in.)

Weight with packaging [kg(lb)]

4.6 (10.12)

Weight without packaging [kg(lb)]

3.2 (7.04)

Console port

RJ45

RTC

Supported

Maximum power consumption [W]

33

Power supply mode

AC built-in

Number of power modules

1

Rated input voltage [V]

100 V to 240 V, 50 Hz/60 Hz

Input voltage range [V]

90 V to 264 V, 47 Hz to 63 Hz

Maximum input current [A]

2

Maximum output power [W]

70

Safety regulation certification

IEC/EN/UL60950-1 IEC/EN/UL62368-1 GB 4943.1

EMC certification

EN 55032 EN 55035 CISPR 32 GB 9254 EN 55024 CISPR 24 GB/T 17618 EN 300 386 VCCI-CISPR 32 AS/NZS CISPR32 IEC 61000-3-2/EN 61000-3-2 IEC 61000-3-3/EN 61000-3-3

Type of fans

Built-in

Heat dissipation mode

Air cooling

Airflow direction

Left to right

Extended slots (standard configuration)

2 x SIC

Number of service board slots

2

Noise at normal temperature (acoustic power) [dB(A)]

52.3 dB(A)

Long-term operating temperature [°C(°F)]

0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage temperature [°C(°F)]

-40°C to +70°C (-40°F to +158°F)

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Long-term operating altitude [m(ft.)]

< 5000 m (16404.2 ft.)

Availability

0.9999924012